V10-CR-S3-I-W-M2

Ürün Kısa Açıklaması
VISOR® V
10 Code Reader, Standard, max.
8 jobs each with 2 detectors, infrared illumination, wide field of view, motorized focus, LAN interface Applications
Identify
8 jobs with 2 detectors each
Barcode: Reading 1
D barcodes: EAN, UPC, RSS, 2/5 Interleaved, 2/5 Industrial, Code 32, Code 39, Code 93, Code 128, GS
1, Pharmacode, Codabar
Datacode: Reading 2
D codes: ECC
200, QR code, PDF 417, ECC
200 GS
1
| Opticial data | ||
|---|---|---|
| Image chip type 
 | Monochrome | |
| Light source 
 | LED | |
| Light color 
 | Infrared | |
| Wavelength [nm] 
 | 850 | |
| LED risk category [RG] 
 | 0 | |
| Explanation of risk category 
 | Acc. to EN 62471 | |
| Resolution 
 | SVGA | |
| Number of pixels (H x V) [px] 
 | 800 x 600 | |
| Imaging chip technology 
 | CMOS | |
| Sensor size [“] 
 | 1/3.6 | |
| Pixel size [µm] 
 | 4.80 | |
| Field of view type 
 | Wide | |
| Focal length [mm] 
 | 5.2 | |
| Opening angle [°] 
 | 48.0 | |
| Min. field of view (X x Y) [mm] 
 | 13 x 10 | |
| Aperture number 
 | 2.8 | |
| Depth of field 
 | Standard | |
| Focus drive 
 | Motorized | |
| Functions | ||
|---|---|---|
| Max. number of jobs 
 | 8 | |
| Max. number of detectors 
 | 2 | |
| Alignment 
 | – | |
| Available detectors 
 | Data code, Barcode | |
| Result processing 
 | – | |
| Pre-processing 
 | Arrangement | |
| Calibration 
 | – | |
| Robotic functions 
 | – | |
| Additional functions 
 | Archiving, Image transmission | |
| Hardware 
 | VISOR® | |
| Network protocol 
 | TCP/IP, Profinet, EtherNet/IP, sFTP, SMB, FTP | |
| Electronic data | ||
|---|---|---|
| Typical current draw [mA] 
 | 350 | |
| Type of voltage source 
 | The device must be supplied by a “Class 2” power supply unit. | |
| Readiness delay [ms] 
 | ≤ 16,000 | |
| Reverse polarity protection 
 | Yes | |
| Overvoltage protection 
 | No | |
| Residual ripple [%] 
 | ≤ 5 Vss, level 3 | |
| Explanation of residual ripple 
 | EN 61000-4-17 | |
| Polarity 
 | PNP/NPN | |
| Short circuit protection 
 | Yes | |
| Input threshold (High) 
 | > UB-1V | |
| Input threshold (Low) 
 | < 3V | |
| Input resistance [kΩ] 
 | > 20 | |
| Max. output current [mA] 
 | 50 | |
| Explanation of max. output current 
 | max. 100 mA on pin 12 | |
| Inductive loads 
 | Typ.: Relay 17 K / 2 H, pneumatic valve 1.4 K / 190 mH | |
| Max. output current (total) [mA] 
 | 200 | |
| Ethernet transmission rate [Mbit/s] 
 | 100 | |
| Number of switchable IOs 
 | 4 | |
| Number of outputs 
 | 2 | |
| Number of inputs 
 | 2 | |
| Encoder functions 
 | No | |
| Mechanical data | ||
|---|---|---|
| Height [mm] 
 | 85.0 | |
| Length [mm] 
 | 45.0 | |
| Width [mm] 
 | 45.0 | |
| Weight [g] 
 | ~ 220 | |
| Front panel material 
 | PMMA | |
| Housing material 
 | Aluminum (cast) | |
| Connection name 
 | Supply | |
| – Number of pins 
 | 12 | |
| – Coding 
 | A | |
| – Thread 
 | M12x1 | |
| – Material 
 | Metal | |
| – Type 
 | Plug | |
| Connection name 
 | LAN | |
| – Number of pins 
 | 4 | |
| – Coding 
 | D | |
| – Thread 
 | M12x1 | |
| – Material 
 | Metal | |
| – Type 
 | Socket | |
| Explanation of ambient temperature: storage 
 | < 95 % humidity, non-condensing | |
| Protection class 
 | IP 65, IP 67 | |
| Explanation of protection class 
 | For C-mount devices, only in combination with protective tube | |
| Vibration and shock resistance 
 | EN 60068-2-6, EN 60068-2-27 | |
 
											 
											